RADIATION EFFECTS TESTING AND SERVICES



Consultation



Designing
Preparation



Testing






Reporting
CONSULTATION AND PROBLEM ANALYSIS
-
Analysis of environmental requirements based on orbit and mission lifetime; ECSS-E-ST-10-04C (fields of particles, fluxes)
-
In-flight dose (TID) end effects calculations based on 3D Mote Carlo modeling; ECSS-E-ST-10-12C -> realistic environmental requirements
-
Relevant electronic components selection and shielding optimization -> lower power, lower mass
-
Planning
-
realistic scheduling
-
optimization: faster -> cheaper irradiation
-
PREPARATION AND DESIGN
-
Test plans and detailed test procedures; ESCC 22900, ESCC 25100, MIL-STD-883 m:1019, 1020.1 1021.3
-
Planning with optimization: faster -> cheaper irradiation
-
Beam requirements: doses/fluences, fluxes, beam shapes, energies
-
Preparation of DUTs for irradiation
-
Electronic equipment selection and design,
-
Supporting electronic equipment selection and design
TESTING
-
Total Ionizing Dose (TID); ESCC 22900, MIL-STD-883 m:1019
-
gamma/electron (Paul Scherrer Institut : Co60)
-
proton (Paul Scherrer Institut: Proton Irradiation Facility)
-
-
Single Event Effects (SEE); ESCC 25100, MIL-STD-883 m:1020.1 and 1021.3, JESD57A, JESD234
-
proton​ (Paul Scherrer Institut: Proton Irradiation Facility)
-
Heavy Ions (HI)
-
REMOTE MODE - we are awaiting your samples and performing tests with customer online supervising during irradiation.
-
REPORTING
-
According to ECSS and ESCIES recommendations
Facilities

PROTONS
Proton Irradiation Facility (PIF)
​
-
Placed at Paul Scherrer Institut, Villigen, Switzerland
-
Member of European Components Irradiation Facilities
-
Provides protons with the following parameters
-
Energy 6 - 230 MeV
-
Fluxes 10^4 - 10^9 p/cm2/s
-
Irradiation area up to 7 cm diameter​
-
HEAVY IONS

HEAVY IONS
Co60 GAMMA RAY
Paul Scherrer Institute certified laboratory
​
-
Co60
-
36 to 360 rad(Si)/hour (ESCC 22900 - "Low Rate")

HEAVY IONS
Radiation Effects Facility (RADEF)
​
-
Placed at University of Jyväskylä, Finland
-
Member of European Components Irradiation Facilities
-
Provides Heavy Ions
-
LET 1 - 60 MeV/mg/cm2
-
​
Cyclotron Resource Centre at Louvain-la-Neuve, Belgium
​
-
Placed at Université catholique de Louvain, Belgium
-
Member of European Components Irradiation Facilities
-
Provides Heavy Ions
-
LET 1 - 60 MeV/mg/cm2
-
​​
CEA / DRF CNRS / IN2P3 GANIL
​
-
Placed in France
-
Provides Heavy Ions
-
LET up to 100 MeV/mg/cm2
-
Co60 GAMMA RAY
HEAVY IONS

PROTON BEAM
Paul Scherrer Institute
​
-
Energy 60 MeV
-
Flux 10^14 p/cm2/s
-
Irradiation area ~1cm diameter